Fire Doors are engineered and tested to prevent the spread of fire in a building. The Spence fire-rated door range covers up to 2 Hours of protection to allow sufficient evacuation time. We manufacture and supply the complete door set; this is the door leaf, frame, and cutouts for hardware.
All Spence fire doors are manufactured using a proprietary core that maintains fire resistance without the need for Fire Bolts. This is important for both safety and compliance given that an activated Fire Bolt fixes the door shut. This creates a greater barrier to entry for the fire department who are not issuing occupancy permits where fire bolts are used but also poses a safety concern if fire bolts are accidentally triggered where there is no fire and trap occupants inside. In addition, if fire bolts are accidentally triggered, the door and jamb cannot easily be removed and replaced creating significant inconvenience and unwanted expense.
To complement our fire door range, we have one of the largest sets of hardware in the Australian market tested for use on our doors. This gives spec flexibility as there are more options to choose from when pairing the preferred hardware with a fire door. This is important given that a door is only fully fire compliant if the hardware has been tested with the core used in manufacturing the fire door in the preferred configuration. For example, door hardware may be ok to use on a single leaf but non-compliant on a pair door.
All Spence Fire doors are custom made. To ensure compliance the chosen function, leaf number, frame type, skin, cladding accessories, wall time, frame dimensions and hardware all need to have been tested with the core that is used to manufacture the door. As a result, Spence can offer compliant fire door sets that cover the following variations:
Things to consider in specifying a fire-rated door are impacted by the building type. Fire-related requirements differ in each of the building classes outlined in the National Construction Code. Attributes like building size, building use, volume/density of people, and accessibility to entry & exit are all considered. Spence’s team can advise on these considerations with respect to your project. Our advice is informed by decades of bringing door safety to residential buildings, hospitals, schools, train stations, and public spaces all around Australia.
A door deemed ‘fire safe’ has met requirements defined in the National Construction Code (NCC). These requirements constitute a door set that is compliant with Australian Standards and holds a certified fire resistance level (FRL). All Spence fire doors are specified and manufactured to the latest Australian Standards - particularly AS 1905.1:2015 which outlines the purpose and material requirements of a fire-resistant door set inclusive of door leaf, frame, hardware, and the surrounding wall.
The Spence team can advise on the next steps of your doorset as compliance goes beyond its manufacture through to its correct installation and maintenance. Regarding installation, this includes an appropriate door/frame gap tolerance, no unapproved drilling or cutting, and fire tags being clearly displayed. Regarding maintenance, an accredited inspector will complete regular inspections to ensure the doorset’s condition and functionality are still up to standard. Get in touch with the Spence Doors team today to advise on these steps and make your project fire safe.